Section

96 Wellplate (in transmission) 

An experiment specific spreadsheet, to be used as sample list, will be sent out to you prior to your scheduled beamtime.

Use the following spreadsheet as sample list an example for 96 wellplates.   Link to Google doc! Example Document




Expand
titleHow to fill out the google spreadsheet for 96 wellplates

Prepare one separate google document for ALL samples! Prepare single sheets within the document for each plate!

Image Added

  • Enter all the key information in the google spreadsheet. It will help beamline staff avoid duplication, errors and misunderstandings. The spreadsheets aim to be a single, comprehensive location of the critical information we need to run each sample. 
  • Samples in the order listed (from top to bottom). Lines with the sample name field left empty are skipped by the beamline, so that you can have gaps in the list that way.
  • Sample name for each well
  • Information on how many shots per well. If more than one, provide the spacing between points (in millimetres).
  • Exposure time (seconds)
  • Every google doc must have same name as label on plate. Please make sure plates are clearly labelled.
  • Include temperature information, plan with enough temperature equilibrium time for each plate measured at non ambient condition!
  • Note the estimated run time for each plate and design your experiment accordingly, especially in regard to the amount of samples! This estimate does NOT include sample / plate changeover and mounting times!


Example below or download Example Spreadsheet here: → Example Document

Image Added




For liquid samples in standard 96 wellplates, please send us the plates with your samples prefilled, sealed and labeled under the following guidelines:

Plate Dimensions

Please use standard wellplates with the following dimensions to accomodate the mounting in our sample holder at the beamline: NK to send through photos and dimensions!

85.5 mm x 127.8 mm

with a 5 mm lip around the bottom. 

Sample preparation

  • Prefill your samples so each well is about half filled with sample volume.
  • Seal your wellplates with samples (we discourage the use of tape seals and prefer heat or pressure sealing).
  • Test the seal of your wellplates before sending the samples to the beamline. The wellplates will be mounted vertically at our sample setup (see here for details) and a good seal is required to avoid leakage. We have seen significant problems with sealing systems at elevated temperatures (even 37 ºC) and we recommend you test this in advance.

Labeling

  • Label your wellplates clearly! The label must be big enough to read and find and resistant to any eventually necessary experiment conditions (heating, cooling, freezing, solvents)
  • The labeling on the wellplate MUST be the same as the label in the prepared google spreadsheet (see description above).

Exceptions

On a case by case basis, there might be exceptions to the way we can run your samples in 96 wellplates. This can include us adding reactants / solutions to plates on site just prior to mounting the plates and running the samples or specific sample preparation that needs to be freshly done before the measurement. Please inquire about these opportunities and arrange these ahead of your beamtime in conversation with the beamline team! Contact information can be found here.


...