CXASAP on MX

CXASAP on MX

Ā 

Background

CX-ASAP is a collection of pipelines and modules for the automatic analysis of chemical crystallography data.

We have incorporated the AS-Brute-individual pipeline into the CX data processing pipeline on MX1 and MX2.

Ā 

What does this mean for me?

The AX-Brute-individual pipeline runs xprep (with all the suggested options) and SHELXT on each hkl produced by the MX data processing pipeline. This means no more quickly running xprep and SHELXT on your data in the middle of the night to see if it is actually what you wanted! šŸ„³

Ā 

What do I need to do before data collection?

You need to provide a suggested chemical formula. There is now a Chemical Formula field in the Dataset tab. Please fill this in so that your SHELXT results have the correct formula. If no formula is provided, the default chemical formula used for solution will be C40H30N6FeCl2O8.

Keep in mind that this information is cleared after each dataset is collected, so you will need to add it every time.

Ā 

How do I use it?

Go to the CX-ASAP_Brute folder in your dataset folder and you will see a bunch of files.

Those with _a on the end are the SHELXT results.

Those with sadabs in the name use sadabs absorption correction.

Ā 

Open a .res and check if the results look anything like you are expecting.

You can open a .res though olex2 or Shelxle on the beamline computers.

Ā 

Ā 

Ā 

What is this doesnā€™t solve my structure the way I want?

All the same data still exists in your dataset folder and in the sadabs folders, as it used to. You can process the XDS_ASCII.HKL_p1 or sad.hkl files with xprep manually if you want to select the non-defualt options. Check out CX - accessing and analysing data on the beamline for more information.

Ā 

Where do I get all the information for my cif?

As before, you need to check the autoprocess.cif file in your dataset folder. This will have synchrotron specific information about your data collection, along with absorption correct details and the crystal size/shape details you filled in at the start of your data collection. See CIF file entries for more info.

Related content

CXASAP for photochemistry experiments
CXASAP for photochemistry experiments
More like this
CXASAP - serial data analysis
CXASAP - serial data analysis
More like this
CX - accessing and analysing data on the beamline
CX - accessing and analysing data on the beamline
More like this
CXASAP for high pressure experiments
CXASAP for high pressure experiments
More like this
CXASAP Summary of pipelines and modules
CXASAP Summary of pipelines and modules
More like this